The condensate enters the Expansion Chamber through Coupling A. The Air is dissipated through the top, which allows the oily condensate to gravity flow from Portal B into the main tank through Portal C. The condensate then enters into Chamber 1 where the condensate flows through the first Coalescing Filter Pack.
The small particles of oil coalesce, joining to form larger "drops." Because oil has a lower specific gravity than water, the oil then rises to the top and exits through Coupling D. The oil that is accumulated is ready for environmentally safe disposal.
|
Meanwhile, "separated" water slowly sinks to the bottom where it is collected by the Pick-up Hose 1. From there the water ravels through Coupling E to Chamber 2 for further separation. The effluent then travels through the Coalescing Filter Pack 2 to remove the maximum gravity separable oil. The separated oil in Chamber 2 exits through Coupling F for proper disposal. The water then exits Chamber 2 through Pick0up Hose, passing through Coupling G and proceeding to the Patented Exterior Activated Carbon Filter Polishing Unit
|